COMMISSIONING
FOX61xLEDE1 25
E1 port configuration This action list shows step by step how to configure an E1 port. The E1 port
will use the Transparent mode for the P12 transport and will be connected to
another E1 port on the same LEDE1 unit.
The following assumptions and identifiers are used:
The LEDE1 unit is assumed to be plugged in slot 5 of the FOX61x.
The LEDE1 unit is assigned.
The E1 port created has the identifier port-1 and transports a transpar-
ent P12 signal.
The P12 signal from port-1 is connected to port-2.
Configure the port-1 general
parameters
Proceed as follows:
1. Navigate to the port configuration dialogue:
AP:/unit-5/port-1, Configuration - General.
2. Select the port termination mode:
Mode = Transparent.
3. Disable the bidirectional protection switching:
Bidirectional = .
4. Execute “Apply”.
Configure the port-1 synchro-
nization parameters
Proceed as follows:
1. Navigate to the port configuration dialogue:
AP:/unit-5/port-1, Configuration - Synchronization.
2. Do not use a synchronization method:
Method = None.
3. Execute “Apply”.
Create a channel on the port-
1
Proceed as follows:
1. Navigate to the port configuration dialogue:
AP:/unit-5/port-1, Configuration - Channels.
2. Create a P12 CTP:
execute “Create Channel…”,
- The “Create Channel” dialogue opens.
3. Configure the CTP:
Index = 1,
execute “OK”.
The E1 port is configured.
Configure port-2 Proceed as follows:
1. Configuration analogue to port 1.
Create cross connections Proceed as follows:
1. Configure the cross connection from the port 1 CTP to the port 2 CTP on
the LEDE1 unit.
2. Select the “Cross connections” view of the FOXCST.
Click on the “Connection Wizard” button: