138 Technical data
Power supply filters
* See EMC filters starting on page 166 for further details.
** See Foot-mount filter (single phase only) on page 165 for further details.
Maximum earth leakage from the MicroFlex e150 is 3.4 mA per phase (230 V, 50 Hz
supply). This value does not include the earth leakage from the AC power filter, which
could be much larger (see EMC filters on page 166).
24 V control circuit supply (X2)
MicroFlex e150
current rating
230 V AC, 1Ø 230 V AC, 3Ø
3 A FI0015A00 + line reactor *
or
FI0029A00 **
FI0018A00 *
6 A FI0015A02 *
or
FI0029A00 **
FI0018A00 *
9 A FI0029A00 ** FI0018A03 *
Description Unit 3 A 6 A 9 A
Nominal input voltage V DC 24
Minimum input voltage V DC 20
Maximum input voltage V DC 30
Maximum ripple % ±10
Typical input current
(not powering feedback device)
A 0.5 - 0.6
Typical input current
(powering feedback device)
A 0.6 - 0.8
Maximum continuous current
@ 24 V DC
A1
Power on surge current (typical)
@ 24 V DC, 100 ms
A4