Electrical installation: input / output 65
Digital inputs - general purpose DIN0, DIN3
Location: X3, pins 17 & 7 (DIN0), 15 & 5 (DIN3)
These general purpose digital inputs are buffered by a TLP280 opto-isolator, allowing
the input signals to be connected with either polarity. The inputs do not share a
common reference. When the MicroFlex e150 is connected to Mint WorkBench, the
digital inputs can be configured using the Digital I/O tool. Alternatively, Mint keywords
including DRIVEENABLEINPUT, RESETINPUT, ERRORINPUT and STOPINPUT can be
used. The state of the digital inputs can be viewed using the Mint WorkBench Spy
window's Axis tab. See the Mint help file for details.
General purpose digital input - DIN0 shown:
Digital input - typical connections from an ABB NextMove e100:
33R
33R
3k3
Vcc
DGND
17
7DIN0-
DIN0+
MicroFlex e150
X3
TLP280
Mint
UDN2982
Mint
DRIVEENABLEOUTPUT
MicroFlex e150
USR GND
DOUT0
DIN0-
17
10k
TLP280
7
10
1
9
DIN0+
USR V+
X11
X3
NextMove e100 / controller
User
supply
24 V
User
supply
GND

Table of Contents

Other manuals for ABB MicroFlex e150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB MicroFlex e150 and is the answer not in the manual?

ABB MicroFlex e150 Specifications

General IconGeneral
BrandABB
ModelMicroFlex e150
CategoryControl Unit
LanguageEnglish

Related product manuals