162 System Manual SCK Gas Sampling System 42/23-81 EN Rev. 4
Wash any cooling water and anti-freeze off the skin immediately with water and
soap.
If cooling water or anti-freeze gets in the eyes despite protective glasses, rinse
them thoroughly under running water, holding the eyelids open.
Observe instructions in the anti-freeze manufacturer's safety data sheet.
Explanation of safety measures: Safety regulations for maintenance work on page
156.
The following conditions must be met:
The service switch is in the ON position, the gas sampling probe is completely
retracted from the kiln (see Operating the service switch on page 159).
The service switch is secured against unauthorized actuation.
The gas sampling system has cooled down.
The EMERGENCY STOP switch is pressed.
Perform the following steps for the control cabinet:
Step Procedure
1
Check general condition of control cabinet with regard to the follow-
ing:
general damage
missing or loose covers
visible damage to connection cables
2
Check control cabinet for dripping water or other liquids.
3
In the event of excessive soiling of the surface of the control cabi-
net, clean with a soft brush or compressed-air.
4
Clean touchscreen, particularly edge areas, with compressed-air
and/or moist cloth (if you use cleaning agents, you can request a
resistance table from ABB Service).
Perform the following steps for the probe retractor:
Step Procedure
1
Check general condition of retractor with regard to the following:
general damage
missing or loose covers
visible damage to electric cables
2
Check hoses and pipes for leaks
3
In the event of excessive soiling of the surface of the retractor,
clean with a soft brush or compressed-air; treat rollers in the same
way.
4
Check condition of drive chain with regard to the following:
chain tension
chain link wear
5
In pneumatic box: Check compressed-air oiler for the following:
damage
leaks
oil level
Requirements