196 System Manual SCK Gas Sampling System 42/23-81 EN Rev. 4
Probe retractor: Checking and tightening the drive chain
Maintain adequate drive chain tension so as to prevent damage to the retractor.
weekly or as required
Always take the following safety measures when performing this work:
Wear the general protective equipment.
Turn the service switch to ON and secure the service switch against unauthor-
ized switching (with a padlock).
Additionally press the EMERGENCY STOP switch.
Do not enter the danger area around the retractor until it is at standstill and the
warning lamps and buzzer are off and the flap valve is closed.
Do not perform the work until the gas sampling system has cooled down.
Explanation of safety measures: Safety regulations for maintenance work on page
156.
The following conditions must be met:
The service switch is in the ON position; the gas sampling probe is retracted
from the kiln (see Operating the service switch on page 159).
The EMERGENCY STOP switch is pressed.
Meaning
Maintenance interval
Safety
measures
Requirements