192 System Manual SCK Gas Sampling System 42/23-81 EN Rev. 4
Perform the following steps to check the filter muffler on the compressed-air motor
(-J83):
Step Procedure
1
Pull the drip cup (1) off the filter muffler -J83.
2
Unscrew filter element.
3
Inspect and, if necessary, replace filter element.
4
Screw filter element back on.
5
Put the drip cup back on.
6
Unlock EMERGENCY STOP switch, turn service switch back to
OFF position and insert probe again using the controller.
WARNING! Probe moves into the kiln. Do not stand in the area of
travel of the probe or probe carriage until the probe is com-
pletely inserted into the kiln and the warning lamps go out.
Instructions