EasyManua.ls Logo

ABB SCK - Page 70

ABB SCK
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70 System Manual SCK Gas Sampling System 42/23-81 EN Rev. 4
Danger Where / in what situa-
tion does the danger
arise?
Preventive action
Risk of burning due
to hot surfaces, hot
gases, jet flames
At the duct opening
when installing the probe
in the rotary kiln
Preferably install the probe
when the rotary kiln is out
of operation.
If you install the probe when
the rotary kiln is in operation:
Wear a face mask against
heat, heat-proof gloves and
protective welder's clothing
and respiratory protection
against toxic gases.
Keep the time in which the
duct opening is open as
short as possible.
Danger due to harm-
ful gases
Due to gases escaping
from the duct opening of
the rotary kiln
Only enter the danger area
around the retractor when
the shutter is closed.
Lock the shutter before
commencing work.
Ensure adequate ventila-
tion of the work place.
If work is unavoidable in the
area of the duct opening,
wear respiratory protection
in addition to the general
protective equipment.
Danger due to harm-
ful anti-freeze
In the cooling water of
the cooling system
Avoid contact with the
cooling water and the anti-
freeze.
Wash any cooling water or
anti-freeze off the skin im-
mediately with water and
soap.
If cooling water or anti-
freeze gets in the eyes de-
spite protective glasses,
rinse them thoroughly un-
der running water, holding
the eyelids open.
Observe instructions in the
anti-freeze manufacturer's
safety data sheet.

Table of Contents