Table A.1: Technical Specifications
(Continued)
ValueProperty
– Relay contacts: Not specified
Any, provided that the cable entry (or quick-release connector) is facing downMounting orientation
A.2 Environmental Specifications
Table A.2: Environmental Specifications
Characteristic/Value/Standard/RegulationProperty
IEC 60664-1Insulation specifications
IIOver voltage category
2Pollution degree
IP66/IP67 (all versions)Protection (EN 60529)
-40° to 70°C (-40° to 158°F)
Below -20°C, the LCD may be blank, but all other work
OK including the safety relay function.
-20° to 70°C (-4° to 158 °F) with quick connector Ex models "QC"
Must not be installed in direct sunlight.
Ambient Operating temperature
(EN/IEC 60068-2-1/2/14)
-40°C/85°C (-40°F/185°F)Ambient Storage and transportation
temperature
(EN/IEC 60068-2-1/2/14)
5 - 95% non-condensingRelative humidity
(EN/IEC 60068-2-78)
Frequency range: 5 - 200 HzVibration sinusoidal operating
Acceleration: 20m/s
2
peak (2 G)(EN/IEC 60068-2-6)
Displacement: 0.15 mm peak
Acceleration: 15GShock operating
(IEC 60068-2-27) – Duration of pulses: 11 ms duration (half sine wave)
– Three shocks in each direction (six pulses in each axis)
8VZZ005286 B 133
A Specifications
A.2 Environmental Specifications