MC96F6432
134 June 22, 2018 Ver. 2.9
Figure 11.17 Input Capture Mode Operation for Timer 1
Figure 11.18 Express Timer Overflow in Capture Mode
T1CNTH/L
Interrupt
Request
(FLAG11)
XX
H
Interrupt Interval Period = FFFF
H
+01
H
+FFFF
H
+01
H
+YY
H
+01
H
Ext. EINT11 PIN
Interrupt
Request
(T1IFR)
FFFF
H
FFFF
H
YY
H
00
H
00
H
00
H
00
H
00
H
T1CNTH/L
Value
Interrupt
Request
(FLAG11)
TIME
1
2
3
4
5
6
n-2
n-1
n
Interrupt Interval Period
0
Count Pulse Period
P
CP
Up-count
T1BDRH/L Load