Fieldbus Interface
103
Introduction
The Fieldbus Interface card permits an EVO 150 control system to communicate with a remote
PLC or computer through a Fieldbus network.
Interface cards are available for: EtherNet/IP, PROFINET IO, and Modbus/TCP.
The Fieldbus interface provides full control of operating mode, guide point position, servo gain,
and actuator speed limit; and permits monitoring of actuator position, end-of-travel status, and
web position.
The Fieldbus interface may be used in conjunction with the front-panel switch pad.
Contact AccuWeb, Inc. for the IP Configuration Utility and example Module Properties
configuration.
Installation
To install the Fieldbus interface card in the EVO 150 controller, follow the steps below:
1. Field installation of the Fieldbus interface card in the EVO 150 Controller:
f) Verify that the power source is off and locked out.
g) Install the Fieldbus interface card by pushing it firmly onto header P3 on the EVO 150
controller assembly.
h) Secure the Fieldbus interface card to the standoffs with four #4-40, 0.25” long machine
screws and four #4 internal tooth star washers provided.
Note: If the control system is ordered with the Fieldbus interface card, these components
will be factory installed and tested prior to shipment.
2. Connections and settings:
a) Install the Ethernet cable through an available cord grip.