EasyManua.ls Logo

AccuWeb EVO 150 - Maintenance

AccuWeb EVO 150
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PointSource and WideArray Edge Detectors
59
Maintenance
Ultrasonic Edge Detectors:
The ultrasonic edge detectors require no periodic maintenance. If a loss of unblocked signal level
is noticed, cleaning of the transducer faces may be required. Clean the transducer faces with a
clean cloth dampened with water or a mild soap solution. DO NOT use harsh solvents as this
may damage the transducer.
Infrared Edge Detectors:
For best performance, clean the black optical windows if they become dusty or dirty. Use a clean,
soft (non-abrasive) cloth dampened with a mild soap solution or a cleaning solution suitable for
camera lenses.
Hi-Temp Edge Detectors:
The Hi-Temp edge detectors require no periodic maintenance. If a loss of unblocked signal level
is noticed, cleaning of the waveguide tubes may be required. Use a vacuum cleaner to remove
debris accumulated within the tubes and wipe the inner surfaces of the angled reflectors (located
on the tips of the tubes) with a clean cloth dampened with water or a mild soap solution.

Related product manuals