PointSource and WideArray Edge Detectors
56
Setup
The following table lists all sensor models. The corresponding values for the controller
parameters, 12, 13, 24, 25, 36, 37, 55 and 56, are set using the Edge Detector Settings Screen,
see page 17.
Sensor
Type
Sensor Model
Number
Sensing Area
Width
inches [mm]
Guide Point
Adjust Range
inches [mm]
Parameter
12 or 13
Parameter
24 or 25
Parameter
36 or 37
Parameter
55 or 56
Notes
PointSource
Ultrasonic
E/D
1.5x3U 4043-XX 0.2 [5] 0.06 [1.6] 1 2 x 0
3x3U 4050-XX 0.2 [5] 0.06 [1.6] 1 2 x 0
4x6U 4060-XX 0.2 [5] 0.06 [1.6] 1 2 x 0
4x12U 4090-XX 0.2 [5] 0.06 [1.6] 1 2 x 0
Ultrasonic
WideArray
E/D
1.5x3.75U 4612-XX 1.4 [36] 1.2 [30] 1 10 0 0
4x3.75U 4621-XX 1.4 [36] 1.2 [30] 1 10 1 0
1.5x5U 4511-XX 2.6 [66] 2.4 [61] 1 16 0 0
4x5U 4500-XX 2.6 [66] 2.4 [61] 1 16 1 0
1.5x9U 4524-XX 6.6 [168] 6.4 [163] 1 36 0 0
4x9U 4520-XX 6.6 [168] 6.4 [163] 1 36 1 0
4x14U 4530-XX 11.4 [290] 11.2 [284] 1 60 1 0
4x21U 4540-XX 18.6 [472] 18.4 [467] 1 96 1 0
PointSource
Infrared
E/D
1.5x3L 4044-XX 0.2 [5] 0.06 [1.6] 1 2 x 1
3x3L 4051-XX 0.2 [5] 0.06 [1.6] 1 2 x 1
4x6L 4061-XX 0.2 [5] 0.06 [1.6] 1 2 x 1
4x12L 4091-XX 0.2 [5] 0.06 [1.6] 1 2 x 1
Infrared
WideArray
E/D
1.5x3.75L 4611-XX 1.4 [36] 1.2 [30] 1 10 0 1
4x3.75L 4620-XX 1.4 [36] 1.2 [30] 1 10 1 1
1.5x5L 4512-XX 2.6 [66] 2.4 [61] 1 16 0 1
4x5L 4501-XX 2.6 [66] 2.4 [61] 1 16 1 1
1.5x9L 4523-XX 6.6 [168] 6.4 [163] 1 36 0 1
4x9L 4521-XX 6.6 [168] 6.4 [163] 1 36 1 1
1.5x14L 4534-XX 11.4 [290] 11.2 [284] 1 60 0 1
4x14L 4532-XX 11.4 [290] 11.2 [284] 1 60 1 1
Digital
Line
Guide
P/E 5100-XX 0.63 [16] 0.43 [11] 2 x x x
In the table above, x indicates don’t care or not used.