Troubleshooting
The following checklist has been provided to assist in the analysis and repair of potential trouble
situations with the Remote Station. If a situation occurs that is not described in this list, contact
AccuWeb for assistance.
Problem Solution
The display does not display any characters. Check item 1 in the table
below.
The display is active but the keys do not work. Check item 2 in the table
below.
The display shows “EEPROM error – Set defaults.” Check item 3 in the table
below.
The display shows “Serial i/o error.” Check items 1, 4 and 5 in the
table below.
Item Description / Repair Procedure
Bad cable connection. If the display is not working, check the interface
cable and replace if bad.
1
Keypad is disabled. Refer to page 2 100 for more information about this
feature.
Non-volatile memory contains bad data. Reset all parameters to their
default values:
3
To reset all parameters to their default values, pre
ss and hold the ENTER
key while cycling AC power to the attached controller. When the power-up
message appears release the ENTER key.
Other remote station is malfunctioning: Make sure that the other remote
station is connected and operating properly. The non-volatile memory in the
other remote station may need to be reset.
4
Digital line guide is malfunctioning: Make sure that the digital line guide
is connected and operating properly. The non-volatile memory in the digital
line guide may need to be reset.
5
Remote Station – Auxiliary
101