Parameters
This section provides a basic procedure for setting the Remote Station parameters and also
describes each parameter in detail.
The Operation section of this manual (page 90) describes the operation of the Remote Station
front panel
keys and display.
Job Profile
J o b P r o f i l e 1
The Remote Station can store up to 25 unique paramete
configurations (called job profiles) that make material
changeover faster and less error-prone. When a job profile
is selected, all previously stored parameter settings fo
that job are instantly recalled.
Range: 1 to 25
To save a new job profile, select an unused profile
numbe
r, then change the other parameters as needed.
To modify an existing job profile, select its profile number,
then ch
ange the other parameters as needed.
To recall a job profile, select the profile number.
Note: When AC power is turned on the system will
automatically reloa
d the job profile that was selected and
in use when AC power was lost.
The default value is 1.
Offset 1
O f f s e t 1 0 . 0 0 0
Offset 1 is typically used for setting the guide point position
- when in Automatic mode the guide will maintain the web
at this position. The offset is displayed in inches o
millimeters.
Range: 16.300” [ 414.0 mm]
The default value is 0.000.
Offset 2
O f f s e t 2 0 . 0 0 0
Offset 2 is typically used for setting a second guide point
position in applications that require PLC control of guide
point position. The controller’s AUXILIARY input
determines which offset is active – Offset 1 or Offset 2.
Refer to page
Range: 16.
300” [ 414.0 mm]
46 for more information about the
AUXILIARY i
nput. The offset is displayed in inches o
millimeters.
The default value is 0.000.
Remote Station - Guide Point Adjust
91