Discrete Isolated Inputs (DC COMMON is connector J9 terminal 9)
AUXILIARY
Switchpad
Connector
Input
Input Action performed when input is activated
Type
J9 terminal
Function
(Param 51)
(Param 52)
selects
AUTO
mode
Select Automatic mode (guide the web using position
feedback from sensors selected by the EDGE A, EDGE
B, or LINE / CENTERLINE inputs).
x
8
AUXILIARY
Select other operating functions. See description of
para
meter 52.
other
function
x
SERVO-
CENTER
1 x x
Select Servo-Center mode (move actuator to servo-
cente
r position).
5 x x Select Manual mode (stop actuator).
MANUAL
6 x x Select Manual mode and In mode (move actuator in).
IN
7 x x Select Manual mode and Out mode (move actuator out).
OUT
selects
AUTO
mode
x Select Input A.
2
EDGE A
other
function
x Select Input A and Automatic mode.
selects
AUTO
mode
x Select Input B.
3
EDGE B
other
function
x Select Input B and Automatic mode.
selects
AUTO
mode
has
CENTERLINE
button
Select Centerline mode.
has
CENTERLINE
button
other
function
Select Centerline mode a
nd Automatic mode.
selects
AUTO
mode
has LINE
button
Select Input C.
Note: T
o select Centerline mode, activate the EDGE A
and EDGE B inputs simultaneously.
LINE /
CENTERLINE
4
Select Input C and Automatic mode.
other
function
has LINE
button
Note: T
o select Centerline mode, activate the EDGE A
and EDGE B inputs simultaneously.
Note: In all tables, x indicates don’t care or not used.