Actuators with limit switches (MM, MME, MN, and MNE) - LUBRICATION:
1) Remove the actuator from the machine.
2) Extend the actuator to its Out end-of-travel limit.
3) Remove the side covers or body extru
sion by removing the hex-head screws.
Note: Fo
r some models this may require removing the thrust tube rod end and end cap.
4) Very lightly lubricate the lead screw with white lithium grease.
Caution: Do
not over-lubricate the lead screw as this could bind the nut and lead screw.
5) Reassemble the actuator.
6) Retract and extend the actuator 20 times to distri
bute grease along the lead screw.
7) Reinstall the actuator and make sure the actuato
r shuts off before it reaches a mechanical
stop.
Actuators with limit switches (MX) - LUBRICATION:
1) Press the MANUAL button, then press the OUT button
to drive the actuator to its Out limit.
2) Remove the actuator from the positive displ
acement guide (PDG).
3) Gain access to the lead screw through the top of th
e actuator next to the cam follower and
spacer. Very lightly lubricate the lead screw with white lithium grease.
Caution: Do
not over-lubricate the lead screw as this could bind the nut and lead screw.
4) Reassemble the actuator in the reverse order as disassembly.
5) Retract and extend the actuator 20 times to distri
bute grease along the lead screw.
6) Reinstall the actuator into the PDG and make su
re the actuator shuts off before it reaches a
mechanical stop.