P1100C/P1200i/P1200B
Condential 5-9
5-2-2 Network FW Upgrade
Procedure
1. Set the connection of Network
(please refer to 4-11-1 and 4-11-2).
2. Open the internet explorer.
3. - Visit "http://192.168.100.10/cgi-bin/
rdupgrade.cgi".
- Click "Browse"
4. - Select the network rmware (*.bin).
- Click "Open".
- Click "Upgrade".
5. The screen will show as right picture, and
after upgrading, the projector will reboot
automatically.