Accord xpC - July, 2001
System Programming - Group 6 Comms Options1
Group six programming is as follows:
1. The first digit entered is 6 for System Options.
2. The second digit is the required system option 1 — 9.
3. The third digit is the option value.
Group 6 — Option 1 Primary Telephone No.
A telephone number of up to 20 digits must be entered here. This is the telephone number
of the Alarm Receiving Centre (ARC).
Enter # to create a two second pause dialling of the ARC telephone number.
Multiple entries may be used, e.g. three consecutive presses would give a
six second pause.
If less than 20 digits are used, end programming by pressing Ö.
To delete a telephone number press # then Ö.
Group 6 — Option 2 Secondary Telephone No.
A telephone number of up to 20 digits may be entered here.
Enter # to create a two second pause in the dialling of the ARC telephone
number. Multiple entries may be used, for example three consecutive presses
would give a six second pause.
If less than 20 digits are used, end programming by pressing Ö.
To delete a telephone number press # then Ö.
Group 6 — Option 3 Account Number
A four to six digit account number must be entered here. Two confirmation beeps are
heard when the Account Number has been accepted.
If less than 6 digits are used, end programming by pressing Ö.
Group 6 — Option 4 User Duress
User 8 can be assigned as User Duress. There are two available options.
0. Duress disabled
1. Duress enabled
This option defaults to 0 (disabled).
Note: Although Duress Codes may set/unset, etc, the Duress signal should be sent as
soon as the four digit code is entered.
No audio or visual indication should be given at any time for Duress, other
than in the event log where the zone numbers are scrolled through. If a keypad
is omitted, the Duress Code must remain active and allow setting and unsetting
to take place.