Accord xpC - July, 2001
1 Dual Report
If set to 1, the alarm reports in Dual mode, i.e. the panel has to communicate successfully
with both primary and secondary telephone numbers.
The communicator shuts down until another report needs to be sent if both reports have
been successfully sent.
If either, or both reports are not successful the panel redials the unsuccessful number(s)
until:
It has successfully reported to both numbers.
It has tried the unsuccessful number(s) a total of five times. A Comms Fail is
given and the communicator shuts down until another report needs to be sent.
Group 7 — Option 2 Dial Type
If this option is set to 0 the panel dials using Pulse dialling, also known as Rotary or Loop
Disconnect
If this option is set to 1 the panel dials using DTMF Dial, also known as Tone.
Note: Although this equipment can use either Pulse or DTMF dialling, only the
performance of the DTMF signalling is subject to regulatory requirements for
correct operation. It is therefore recommended that the equipment is set to use
DTMF dialling.
This option defaults to 1 (DTMF).
Group 7 — Option 3 Prevent Full Set if Line Fail
If disabled (0) the panel can be full set if a Line Fail has been detected.
If enabled (1) the panel can not be full set if a Line Fail has been detected.
This option defaults to 0 (disabled).
Group 7 — Option 4 Bell Delay
If this option is disabled (set to 0) there is no Bell Delay.
If this option is enabled (set to 1) there is a 10 minute delay between an alarm and the
activation of internal and external sounders. During this time the entry beeps sound if the
unsetting procedure is initiated and the Bell Delay is overridden if a Line Fail or Comms
Fail condition occurs.
This option defaults to 0 (No Bell Delay).
Note: Bell Delay is over-ridden in set states that are not programmed to
communicate (Group7 - Option 6).