EasyManua.ls Logo

ADT ACCORD XPC - 6 - PA Silent; 7 - PA Audible; 8 - Push-to-Set; 9 - Fire

ADT ACCORD XPC
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
Accord xpC - July, 2001
until a valid code is entered at the keypad. The activation is reported via the Accord xpC
dialler.
It is strongly recommended that a zone programmed as PA Silent is programmed in one
of the following ways:
Programmed as PA Silent in Group 1 (Full Set), 2 (Part Set) and 3 (Night Set).
Programmed as PA Silent in Group 1 (Full Set), and, 0 (Not Used) or PA Silent
in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
7 — PA Audible
A PA Audible zone is assigned to a panic button. Activation of a PA Audible zone
initiates a full alarm condition. The activation is also reported via the Accord xpC
downloader.
It is strongly recommended that a zone programmed as PA Audible is programmed in
one of the following ways:
Programmed as PA Audible in Groups 1 (Full Set), 2 (Part Set) and 3 (Night
Set).
Programmed as PA Audible in Group 1 (Full Set), and, 0 (Not Used) or PA
Audible in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
8 — Push-to-Set
A Push-to-Set zone becomes active when the setting procedure is intiated. Setting will
terminate if the Accord xpC detects a change in state (Set/Unset) on a Push-to-Set zone
Note: For Push-to-Set zones to operate Group 7 - Option 5 (Push to set) must be
enabled. There is a five second delay between the activation of the Push-to-Set
zone and the setting of the system.
Push-to-Set zones have no effect when the system is set .
9 — Fire
A Fire zone is used for fire detection devices with normally closed outputs.
It is strongly recommended that a zone programmed as Fire is programmed in one of the
following ways:
Programmed as Fire in Group 1 (Full Set), 2 (Part Set) and 3 (Night Set).
Programmed as Fire in Group 1 (Full Set), and, 0 (Not Used) or Fire in Groups 2
(Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
Activation of a Fire zone at any time causes the Loud-Speaker, Keypad Sounder and
Bell outputs to pulse on and off.

Table of Contents

Related product manuals