41
Accord xpC - July, 2001
until a valid code is entered at the keypad. The activation is reported via the Accord xpC
dialler.
It is strongly recommended that a zone programmed as PA Silent is programmed in one
of the following ways:
Programmed as PA Silent in Group 1 (Full Set), 2 (Part Set) and 3 (Night Set).
Programmed as PA Silent in Group 1 (Full Set), and, 0 (Not Used) or PA Silent
in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
7 — PA Audible
A PA Audible zone is assigned to a panic button. Activation of a PA Audible zone
initiates a full alarm condition. The activation is also reported via the Accord xpC
downloader.
It is strongly recommended that a zone programmed as PA Audible is programmed in
one of the following ways:
Programmed as PA Audible in Groups 1 (Full Set), 2 (Part Set) and 3 (Night
Set).
Programmed as PA Audible in Group 1 (Full Set), and, 0 (Not Used) or PA
Audible in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
8 — Push-to-Set
A Push-to-Set zone becomes active when the setting procedure is intiated. Setting will
terminate if the Accord xpC detects a change in state (Set/Unset) on a Push-to-Set zone
Note: For Push-to-Set zones to operate Group 7 - Option 5 (Push to set) must be
enabled. There is a five second delay between the activation of the Push-to-Set
zone and the setting of the system.
Push-to-Set zones have no effect when the system is set .
9 — Fire
A Fire zone is used for fire detection devices with normally closed outputs.
It is strongly recommended that a zone programmed as Fire is programmed in one of the
following ways:
Programmed as Fire in Group 1 (Full Set), 2 (Part Set) and 3 (Night Set).
Programmed as Fire in Group 1 (Full Set), and, 0 (Not Used) or Fire in Groups 2
(Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
Activation of a Fire zone at any time causes the Loud-Speaker, Keypad Sounder and
Bell outputs to pulse on and off.