ADTECH9 Series CNC Maintenance Manual
- 142 -
Z Machine Limit ELevel<●>
A Machine Limit ELevel<●>
B Machine Limit ELevel<●>
C Machine Limit ELevel<●>
Range : 0~1
Unit : None
Authority : Super Admin
Default : 0
Effective time : After restarted
Note : Specific parameter settings depend on the interface level instructions of
selected button or photoelectric sensor switch.
Scanning mode is integrated by the system and can’t be shielded. The
scanning mode inputs signal by accessing specified function number, and
uses software anti-interference detection technology to check whether
limit alarm occurs or has no interference. This requires certain time to
check, and thus the real time isn’t as well as interrupted limit. However,
in most cases (at 10mm/min processing speed), it can meet the
requirement on processing safety check.
The hardware response function of hard limit is prior to scanning
response function, i.e. if the hardware response is enabled, it will quicken
the response speed directly. It should be noted that the hardware response
function only can stop pulse in instant mode. Therefore, the instant stop
mode may cause mechanical vibration if the speed is too high. While
software scanning mode uses maximum acceleration mode and
decelerates according to the maximum acceleration set to every axis by
the user (parameter P2.029), and therefore overshot will occur.
024 X Pulse Command Format (restart)
Y Pulse Command Format( restart)
Z Pulse Command Format( restart)
A Pulse Command Format( restart)
B Pulse Command Format( restart)
C Pulse Command Format (restart)