ADTECH9 Series CNC Maintenance Manual
- 149 -
Default : 2000
Effective time : Instant
Note : Set the maximum acceleration of every axis. This setting will affect the
track speed optimization of pretreatment to every axis. If a high value is
set, the axis response time will be shortened and characteristics of the
motor will be improved according to the machine tool.
This parameter also affects the home function and limit stop function.
Hard limit function: Use hard limit in software scanning mode, in which
the hard limit decelerates and stops according to the maximum
acceleration of this axis. Therefore, if this value is too high, the machine
tool will stop in emergency, and if this value is too low, it will cause too
much overshoot.
Home function: the home acceleration of every axis uses this value.
036 X Servo Home Dir
Y Servo Home Dir
Z Servo Home Dir
A Servo Home Dir
B Servo Home Dir
C Servo Home Dir
Range : 0~1
Unit : None
Authority : Super Admin
Default : 0
Effective time : Instant
Note : This parameter determines the Z phase search direction when servo Z
phase enable parameter is enabled in P2.015.
0: Positive
1: Negative
037 X Ext Home Enable
X Ext Home Enable
Z Ext Home Enable

Table of Contents

Other manuals for Adtech CNC9650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech CNC9650 and is the answer not in the manual?

Adtech CNC9650 Specifications

General IconGeneral
BrandAdtech
ModelCNC9650
CategoryControl Systems
LanguageEnglish

Related product manuals