ADTECH9 Series CNC Maintenance Manual
- 150 -
A Ext Home Enable
B Ext Home Enable
C Ext Home Enable
Range : 0~1
Unit : None
Authority : Super Admin
Default : 1
Effective time : Instant
Note : When mechanical home mode is selected, this parameter determines
whether external deceleration switch should be searched. If this parameter
is set to 0, and P2.015 (servo Z phase enable) is also set to 0, the home
mode sets current point as the home directly in mechanical mode.
0: No
1: Yes
038 X Encoder Logic Dir
Y Encoder Logic Dir
Z Encoder Logic Dir
A Encoder Logic Dir
B Encoder Logic Dir
C Encoder Logic Dir
Range : 0~1
Unit : None
Authority : Super Admin
Default : 0
Effective time : Instant
Note : When the logic direction obtained by handheld box encoder is reverse to
the actual motion direction of the axis, set this parameter to perform
in-phase setting.
0: positive direction
1: negative direction
039 X-axis return-to-zero 2
nd