ADTECH9 Series CNC Maintenance Manual
- 151 -
Y-axis return-to-zero 2
nd
segment leave speed
Z-axis return-to-zero 2
nd
segment leave speed
A-axis return-to-zero 2
nd
segment leave speed
B-axis return-to-zero 2
nd
segment leave speed
C-axis return-to-zero 2
nd
segment leave speed
040 X-axis return-to-zero 3
rd
segment detection speed
Y-axis return-to-zero 3
rd
segment detection speed
Z-axis return-to-zero 3
rd
segment detection speed
A-axis return-to-zero 3
rd
segment detection speed
B-axis return-to-zero 3
rd
segment detection speed
C-axis return-to-zero 3
rd
segment detection speed
Range : 1~20000
Unit : mm/min
Authority : Super Admin
Default : 100, 60
Effective time : Instant
Note : Used to set the speed parameters of mechanical resetting; the specific
effective sequence is as follows:
Resetting speed āā> (when detecting external zero switch) deceleration
āā> scanning speed
041 X axis pitch compensation function enable
Y axis pitch compensation function enable
Z axis pitch compensation function enable
A axes pitch compensation function enable
B axis pitch compensation function enable
C axis pitch compensation function enable
Range : OFF ON
Unit : None
Authority : Super Admin
Default : OFF
Effective time : Instant
Note : Set to ON and the pitch compensation of axis X, Y, Z, 4, B, C is valid.