ADTECH9 Series CNC Maintenance Manual
- 161 -
Range : None
Unit : None
Authority : None
Default : None
Effective time : Instant
Note : Clear the accumulated value of current processing pieces
013 Maximum cumulative processing number
Range : 0~999999
Unit : None
Authority : None
Default : 0
Effective time : Instant
Note : When this value is set, the system prompts alarm if the cumulative
processing number in automatic mode is greater than or equals to this
value. The proceeding can be continued when the P3.011 parameter is
cleared.
014 Import CSV system configuration
Range : None
Unit : None
Authority : None
Default : None
Effective time : Restart
Note : Import the CSV system configuration of the manufacturer into the system
015 Startup display module
Range : Select
Unit : None
Authority : Operation admin
Default : ABS
Effective time : Instant
Note : Select default boot screen from absolute position, relative position and