ADTECH9 Series CNC Maintenance Manual
- 171 -
Effective time : Instant
Note : When set to ON, the value specified by S in M03Sxxxx instruction is
invalid, and the spindle speed uses the value specified by P5.031.
011 Mechanical spindle first gear speed (rpm)
012
Mechanical spindle second gear speed (rpm)
013 Mechanical spindle third gear speed (rpm)
014 Mechanical spindle fourth gear speed (rpm)
Range : 1~1000000
Unit : rpm
Authority : Operation admin or higher
Default : 24000
Effective time : Instant
Note : This parameter is used for L version system of lathe, to the maximum
speed of the version, set the maximum speed of each mechanical position
of the lathe spindle relative to M41 M42 M43 M44.
015 Spindle stop delay (ms)
Range : 0~60000
Unit : None
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : To set the delay time after the spindle stops
016 Alarm off spindle enable
Range : 0~1
Unit : None
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : To set whether to automatically turn off the spindle after setting the

Table of Contents

Other manuals for Adtech CNC9650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech CNC9650 and is the answer not in the manual?

Adtech CNC9650 Specifications

General IconGeneral
BrandAdtech
ModelCNC9650
CategoryControl Systems
LanguageEnglish

Related product manuals