49
SET EDT ALARM, information includes (Fig. 46) -
> Graphic EDT (meaning Elapsed Dive Time)
> Time Set Point value (:sec), flashing if ON is selected, with TIME icon
> Set Point ON or OFF, flashing
• Pressing/releasing the S button momentarily (< 2 seconds) will toggle
between ON and OFF.
• Pressing/releasing the A button momentarily (< 2 seconds) will accept the
ON/OFF setting.
> If OFF is accepted, operation will advance to Set RDI.
> If ON is accepted, the Time Set Point value (minutes) will flash.
• Depressing the S button will scroll upward through the
Set Points at a rate of 8 per second from :05 to :30
(:sec) in increments of 1 second.
• Pressing and releasing the S button momentarily and
repeatedly (< 2 seconds each time) will step upward
through the Set Points one at a time.
• Pressing and releasing the M button momentarily and
repeatedly (< 2 seconds each time) will step back
through the Set Points one at a time.
• Pressing and releasing the A button momentarily (< 2
seconds) will accept the Set Point and access Set EDT
Alarm.
• Depressing the M button for 2 seconds, or if no button is
pressed during a period of 2 minutes, operation will
revert the SURF MAIN screen.
Fig. 46 - SET EDT
ALARM