57
• Pressing and releasing the M button momentarily and
repeatedly (< 2 seconds each time) will step back
through the Set Points one at a time.
• Pressing and releasing the A button momentarily (< 2
seconds) will accept the Set Point and revert to Set U.
• Depressing the M button for 2 seconds, or if no button is
pressed during a period of 2 minutes, operation will
revert the SURF MAIN screen.
SERIAL NUMBER (SN)
• Depressing the A and S buttons simultaneously for 6
seconds while viewing the SURF MAIN screen will
access the SN screen displaying (Fig. 56):
> Graphic SN
> Factory programmed Serial Number of the F10
> Firmware revision number (e.g., graphic r1A)
• Depressing the A and S buttons simultaneously for 2
seconds will revert to the SURF MAIN screen.
• Depressing the M button for 2 seconds, or if no button is
pressed for a period of 2 minutes, operation will revert to
the SURF MAIN screen.
NOTE: This information will be required if a
unit is sent to AERIS for evaluation or service.
Record it in the table provided in the back of
this manual, and retain the sales receipt.
Fig. 56 - SN