EasyManuals Logo

Agilent Technologies 8753ET Manual Supplement

Agilent Technologies 8753ET
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
kl507ets
CAL Z0:
LINE Z0
SYSTEM Z0
SET REF:
THRU
REFLECT
RETURN
TRL Option
Menu
ENHANCED
RESPONSE
RESPONSE
RESPONSE
& ISOL'N
S11
1-PORT
S22
1-PORT
FULL
2-PORT
TRL*/LRM*
2-PORT
RECEIVER
CAL
Calibrate
Menu
OPEN (M)
OPEN (F)
DONE:
OPENS
Opens
Menu
SHORT (M)
SHORT (F)
DONE:
SHORTS
Shorts
Menu
SELECT
CAL KIT
SAVE
USER KIT
MODIFY
[ ]
RETURN
Cal Kit
Menu
EXTENSIONS
on OFF
EXTENSION
INPUT A
EXTENSION
INPUT B
EXTENSION
PORT 1
EXTENSION
PORT 2
RETURN
Reference
Plane Menu
PORT
EXTENSIONS
VELOCITY
FACTOR
SET Z
ADAPTER
REMOVAL
TESTSET SW
CONTINUOUS
ALTERNATE
A and B
CHOP
A and B
RETURN
Æ
Calibrate
More Menu
RECALL
CAL PORT 1
RECALL
CAL PORT 2
RETURN
Recall Cal Sets
Menu
DEFINE
STANDARD
SPECIFY
CLASS
LABEL
CLASS
LABEL
KIT
TRL/LRM
OPTION
KIT DONE
(MODIFIED)
Modify Cal Kit
Menu
S11A
S11B
S11C
S22A
S22B
S22C
MORE
SPECIFY
CLASS DONE
Specify Class
Menu
FWD TRANS
REV TRANS
FWD MATCH
REV MATCH
RESPONSE
RESPONSE
& ISOL'N
MORE
SPECIFY
CLASS DONE
Specify Class
More Menu
SPECIFY:
TRL THRU
TRL
REFLECT
TRL LINE
OR MATCH
SPECIFY
CLASS DONE
Specify Class
More Menu
SELECT
LETTER
SPACE
BACK
SPACE
ERASE
TITLE
DONE
Label Select
Kit Menu
FWD TRANS
REV TRANS
FWD MATCH
REV MATCH
RESPONSE
RESPONSE
& ISOL'N
MORE
LABEL
CLASS DONE
Label Class
More Menu
S11A
S11B
S11C
S22A
S22B
S22C
MORE
LABEL
CLASS DONE
Label Class
Menu
LABEL:
TRL THRU
TRL
REFLECT
TRL LINE
OR MATCH
LABEL
CLASS DONE
Label Class
More Menu
2.4mm
85056
2.92*
85056K
2.9mm
other kits
TRL 3.5mm
85052C
7-16
85038
3.5mmC
85033C
RETURN
Select Cal Kit
More Menu
7mm
85031
3.5mmD
85033D/E
N 50W
85032F
N 50W
85032B/E
N 75W
85036
USER KIT
MORE
RETURN
Select Cal Kit
Menu
Calibration Factor Softkey Path
Power Loss Softkey Path
HELP ADAPT
REMOVAL
RECALL CAL
STETS
ADAPTER
DELAY
ADAPTER:
COAX
WAVEGUIDE
REMOVE
ADAPTER
RETURN
Adapter
Removal Menu
TAKE RCVR
CAL SWEEP
RETURN
Rcvr Cal
Menu
OMIT
ISOLATION
DO BOTH
FWD + REV
FWD ISOL 'N
ISOL 'N STD
REV ISOL 'N
ISOL 'N STD
ISOLATION
DONE
2-Port Isolation
Menu
DO BOTH
FWD + REV
FWD TRANS
THRU
FWD MATCH
THRU
REV TRANS
THRU
REV MATCH
THRU
STANDARDS
DONE
2-Port Trans.
Menu
FORWARD:
OPENS
SHORTS
LOAD
REVERSE:
OPENS
SHORTS
LOAD
STANDARDS
DONE
2-Port Reflection
Menu
REFLECTION
TRANS-
MISSION
ISOLATION
DONE
2-PORT CAL
Full 2-Port
Menu
THRU
THRU
S11 REFL
OPENS
S22 REFL
OPENS
ISOLATION
LINE/MATCH
DONE
TRL/LRM
TRL/LRM
Cal Menu
OMIT
ISOLATION
DO BOTH
FWD + REV
FWD ISOL 'N
ISOL 'N STD
REV ISOL 'N
ISOL 'N STD
ISOLATION
DONE
TRL/LRM
Isolation Menu
DO BOTH
FWD + REV
LN/MATCH1
LOAD
LN/MATCH2
LOAD
DONE
LINE / MATCH
Line / Match
Menu
SHORT (M)
SHORT (F)
OPEN (M)
OPEN (F)
THRU
Response
Menu
RESPONSE
ISOL 'N STD
DONE RESP
ISOL 'N CAL
Response &
Isolation Menu
REVERSE:
OPENS
SHORTS
LOAD
DONE
1-PORT CAL
S22 1-Port
Menu
FORWARD:
OPENS
SHORTS
LOAD
DONE
1-PORT CAL
S11 1-Port
Menu
S11/S21
ENH. RESP.
S22/S12
ENH. RESP.
ENH. REFL.
on OFF
RETURN
Enhanced
ResponseMenu
REFLECT'N
TRANS-
MISSION
ISOLATION
DONE
***
ENH RESP
Enh. Resp.
Cal. Menu
DO BOTH
THRUS
***
TRANS
***
THRU
MATCH
***
THRU
STANDARDS
DONE
Enh. Resp.
Trans. Menu
OMIT
ISOLATION
ISOL'N
***
ISOLATION
DONE
Enh. Resp.
Isolation Menu
:
***
OPENS
SHORTS
LOAD
STANDARDS
DONE
Enh. Resp.
Refl. Menu
Menu Map For Cal (8753ES only)
1. When two ECal modules are used in a measurement, the routine will pause to allow you to insert
the next module. A "CONTINUE ECal" and "ABORT ECal" menu will be displayed during the pause.
2. When "MAN'L THRU" is turned "ON", the calibration routine will pause and allow you to insert your own thru.
A "CONTINUE ECal" and "ABORT ECal" menu will be displayed during the pause.
*** Represents "FORWARD"/"FWD" when calibrating the forward path or "REVERSE"/ "REV" when calibrating the reverse path.
ECal
Config Menu
MODULE
A b
CONFIDENCE
CHECK
MODULE
INFO
OMIT ISOL
ON off
ISOLATION
AVERAGES
MAN’L THRU
on OFF
RETURN
SET CONF
STANDARD
PARAMETER
[S11]
TRACE TYPE
[DATA]
AUTO SCALE
ECal
SERVICE
RETURN
ECal
Confidence
CLEAR LIST
YES
NO
Clear List
Menu
PWRMTR CAL
OFF
EACH SWEEP
ONE SWEEP
TAKE CAL
SWEEP
NUMBER of
READINGS
PWR LOSS
on OFF
LOSS/SENSR
LISTS
RETURN
Power Meter
Cal. Main Menu
FREQUENCY
CAL
FACTOR
DONE
Seg. Edit (Cal
Factor) Menu
FREQUENCY
LOSS
DONE
Seg. Edit (Pwr.
Loss) Menu
USE SENSOR
A / B
CAL FACTOR
SENSOR A
CAL FACTOR
SENSOR B
POWER
LOSS
RETURN
Pwr. Loss/Sens.
Lists Menu
SEGMENT
EDIT
DELETE
ADD
CLEAR
LIST
DONE
Segment
Modify Menu
SPECIFY
OFFSET
LABEL
STD
STD DONE
(DEFINED)
Define Delay/
Thru Menu
SPECIFY
OFFSET
LABEL
STD
STD DONE
(DEFINED)
Define Short
Menu
C0
C1
C2
C3
SPECIFY
OFFSET
LABEL
STD
STD DONE
(DEFINED)
Define Open
Menu
STD TYPE:
OPEN
SHORT
LOAD
DELAY /
THRU
ARBITRARY
IMPEDANCE
MODIFY STD
DEFINITION
RETURN
Define Standard
Menu
TERMINAL
IMPEDANCE
FIXED
SLIDING
SPECIFY
OFFSET
LABEL
STD
STD DONE
(DEFINED)
Def. Arbitrary
Imped. Menu
FIXED
SLIDING
OFFSET
SPECIFY
OFFSET
LABEL
STD
STD DONE
(DEFINED)
Define Load
Menu
OFFSET
DELAY
OFFSET
LOSS
OFFSET
Z0
MINIMUM
FREQUENCY
MAXIMUM
FREQUENCY
COAX
WAVEGUIDE
STD OFFSET
DONE
Specify Offset
Menu
SELECT
LETTER
SPACE
BACK
SPACE
ERASE
TITLE
DONE
Label Standard
Menu
ECal
Service Menu
ECal STD
[CONF]
REFL STD
[ 0 ]
PARAMETER
[S11]
TRACE TYPE
[DATA]
AUTO SCALE
RETURN
Cal
ECal
Menu
MODULE
A b
S11
1-PORT
S22
1-PORT
FULL
2-PORT
S11/S21
ENH. RESP.
S22/S12
ENH. RESP.
CONFIGURE
[MODULE A]
RETURN
CORRECTION
on OFF
INTERPOL
on OFF
CALIBRATE
MENU
RESUME CAL
SEQUENCE
ECal
MENU
CAL KIT
[ ]
PWRMTR CAL
[OFF]
MORE
Correction
Menu
CONTINUE
ECal
ABORT
ECal
ECal
Pause Menu
1, 2
1, 2
1, 2
1
1

Table of Contents

Other manuals for Agilent Technologies 8753ET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8753ET and is the answer not in the manual?

Agilent Technologies 8753ET Specifications

General IconGeneral
BrandAgilent Technologies
Model8753ET
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals