24
󱒸󱓙󱓊󱓕󱒅󱒜
Makesurethatallcompartmentcoversarein
placeandlatched.
󱒸󱓙󱓊󱓕󱒅󱒝
Setupthemachineinthefollowingstate:
‒Putthemachineonafirm,levelsurface.
‒Platformposition:center
‒Platformload:0kg
‒Flyjibangle:horizontal(ifequipped)
‒Boomelevation:minimum
‒Boomrotation:rearcenter
LowerControlsCheck2‒2
Dothechecksfirstwiththelowercontrols,
thenwiththeuppercontrols.
󱒸󱓙󱓊󱓕󱒅󱒞
Turnthekeyswitchto“LOWERCONTROL”
andmakesurethatthealarmbuzzersounds
forabout3seconds,justafterturningon.
DANGER
Ifthebuzzerdoesnotsoundproperly,
themachineisfaulty.Donotusethe
faultymachine.
󱒸󱓙󱓊󱓕󱒅󱒖󱒕
Holdthepre-startcheckswitchup.
Makesurethealarmbuzzersoundsforabout
3secondsafterthepre-startcheckswitch
hasbeenheldup.
NOTICE
Ifthebuzzerdoesnotstopsounding,
theboomfunctionsaredisabled.
󱒸󱓙󱓊󱓕󱒅󱒖󱒖
Starttheengineand,idletheenginefor
warmingup.
󱒸󱓙󱓊󱓕󱒅󱒖󱒗
Makesuretherearenostrangesoundscome
fromanypart.
󱒸󱓙󱓊󱓕󱒅󱒖󱒘
Checkthatallsafetysystemsarefunctioning
properly.
‒Emergencystop:pushtheemergency
stopbuttonwhileoperatingtheboom,
andmakesurethatboththeboom
operationandtheenginestop.
‒Emergencypump:Makesurethat
theboomcanbeoperatedwhilethe
emergencypumpisbeingoperated.
󱒸󱓙󱓊󱓕󱒅󱒖󱒙
Checkthatnooilisleakingfromthe
hydrauliccomponents,hosesandpipes.
󱒸󱓙󱓊󱓕󱒅󱒖󱒚
Checktheboomtelescopingwireropesfor
anydamages.
‒Nowobbleorunsteadymovementswhen
telescopingtheboom.
‒Nodamageatthewireropeends.
󱒸󱓙󱓊󱓕󱒅󱒖󱒛
Leavethemachineforafewminuteswith
theboomfullyextended,andfullyraised.
Checkvisuallythattheboomdoesnot
descendonitsown.
UpperControlsCheck2‒3
󱒸󱓙󱓊󱓕󱒅󱒖󱒜
Turnthekeyswitchto“UPPERCONTROL.
󱒸󱓙󱓊󱓕󱒅󱒖󱒝
Wearthesafetyharnessandgetonthe
platformandclosegate.
Aftergettingontheplatform,immediately
hookthesafetyharnesstothelanyard
anchoragepoint.
󱒸󱓙󱓊󱓕󱒅󱒖󱒞
Starttheengine.
󱒸󱓙󱓊󱓕󱒅󱒗󱒕
Rotatetheplatformandmakesurethatthe
platformrotatessmoothlywithoutexcessive
freeplay.
󱒸󱓙󱓊󱓕󱒅󱒗󱒖
Checkthatallsafetysystemsarefunctioning
properly.
‒Emergencystop:pushtheemergency
stopbuttonwhileoperatingtheboom,
andmakesurethatboththeboom
operationandtheenginestop.
‒Footswitch:whileoperatingtheboom,
releasethefootswitch,andmakesurethe
boomoperationstops.
‒Emergencypump:Makesurethat
theboomcanbeoperatedwhilethe
emergencypumpisbeingoperated.

Table of Contents