41
󱒨󱓍󱓆󱓕󱓙󱓊󱓗󱒅󱒞
EmergencyOperation
NOTICE
Iftheemergencyoperationwasdone
becauseofamalfunction,immediately
stoptheoperation,andhavethe
machinecheckedandrepaired.
EmergencyStop1.
Usetheemergencystopbutton.
Whenthisbuttonispushedin,
theenginestopsandallofthe
functionsaredisabled.
Pushintheemergencystopbuttoninthe
followingcases;
(1) Whenapersonintheplatformstopsallof
themachinemovementstoavoidhazards.
(2) Whenapersononthegroundjudgesthat
theoperationfromtheplatformisunsafe.
(3) Whenthemachineisuncontrollabledue
tomalfunction.
M085M221
EmergencyStopButton
g.9‒1
M082M323
EmergencyStopButton
g.9‒2
EmergencyLowering2.
Iftheengineormainpumpfails,
usetheemergencypumpto
lowertheplatform.
NOTICE
• Operatetheemergencypumpevery
other30seconds.Thecontinuous
operationinexcessof30secondsmay
causethedamagedemergencypump.
M082M420
30seconds
orless
30seconds
ormore
Pause
Operate
Pause
Operate
30seconds
orless
30seconds
ormore
g.9‒3
• Travelingoperationisnotpossible
whenoperatingwiththeemergency
pump.
• Theemergencypumprunsoffthe
battery.
UpperControls(from2‒1
platform)
M085F421
EmergencyPumpSwitch
g.9‒4