ElectrocutionHazards1.
DANGER
• Thismachineisnotelectrically
insulated.Donotusethemachinenear
electricpowerlines.
• Keepasafedistancefromelectricpower
linesandapparatus.Forsafedistance,
checkyournationalorlocalregulations.
Ifnonationalorlocalregulationis
available,usethetablebelow.
M085E100
fig.1‒1
Voltage
(PhasetoPhase)
MinimumSafe
ApproachDistance
0to300V AvoidContact
over300Vto50kV 3.05m
over50kVto200kV 4.60m
over200kVto350kV 6.10m
over350kVto500kV 7.62m
over500kVto750kV 10.67m
over750kVto1000kV 13.72m
table1-1
• Keepawayfromthemachineifit
contactsenergizedpowerlines.Until
energizedpowerlinesareshutdown,
anypersonsintheplatformmustnot
operatethemachineandanypersons
onthegroundmustnottouchthe
machine.
• Donotusethemachineduring
lightningorstorms.Stopoperationin
badweather.
• Donotusethemachineasagroundfor
welding.
TipOverHazards2.
DANGER
• Donotexceedtheplatformcapacityas
indicatedontheserialnumberplate.
M085E200
fig.1‒2
• Donothangorattachloadstothe
machine.Spreadloadsevenlyonthe
platform.
• Donotusethemachineasacraneor
lift.
M085E300
fig.1‒3
SafetyRules