Use and Maintenance Manual A12 JE A15 JE A17 JE A12 JED A15 JED Series
Page 45
A)
ON-OFF key and ground/platform control panel selector
B)
Emergency STOP button
C)
Diesel motor generator start button (models A12 JED - A15 JED)
D)
User interface display
E)
Powered-on machine warning light
F)
Battery recharge indicator
G)
Oil warning light
H)
Alternator warning light
L)
Motor head temperature warning light
M
Air filter warning light
N)
PANTOGRAPH LIFTING/LOWERING lever
O)
BOOM LIFTING/LOWERING lever
P)
JIB LIFTING/LOWERING lever
Q)
TELESCOPIC BOOM OUT/IN lever
R)
TURRET ROTATION lever
S)
PLATFORM ROTATION lever
T)
PLATFORM LEVEL compensation lever
U)
JIB ROTATION lever (OPTIONAL)
5.2.1. On-off key and control panel selector (A)
The on-off key located on the ground control panel is used to:
turn ON the machine by selecting one of the two control panels:
o Platform control panel enabled with locking key switch set to platform symbol. Stable key position with possibility to
extract the key.
o Ground control panel enabled (for emergency operations) with locking key switch set to turret symbol. Position with
action to be kept. When the key is released the machine is turned off.
Turn OFF the control circuits by turning it to OFF.
5.2.2. Emergency stop button (B)
By pressing this button the machine (as well as the heat engine) is completely stopped; by rotating it of 1/4 turn (clockwise) the
machine can be turned ON by means of the ON-OFF key.
5.2.3. Diesel motor generator start button (C) (models A12 JED - A15 JED)
Holding the ON-OFF key in position “ground control panel”, the Diesel motor generator can be started by means of the relevant
switch.
In “0” position the Diesel motor generator is off.
In “3 sec” position the plugs pre-heating takes place (only for engines with plugs).
In “Start” position the motor starts.
5.2.4. User interface display (D)
The multifunction display for machine/user interface is used to:
Display the operation parameters of the machine during normal functioning or in the event of a fault;
working hours of the electric pump and electric drive motors (the working hours are displayed in the format HOURS:
MINUTES and the finale E);
working hours of Diesel generator (the working hours are displayed in the format HOURS: MINUTES and the finale D);
working hours of the optional emergency CC electric pump (when 12V electric power is selected the working hours are
displayed in the format HOURS: MINUTES and the finale M);
Battery charge level (only electrical models E).