Use and Maintenance Manual A12 JE A15 JE A17 JE A12 JED A15 JED
Series
Page 47
5.3. Platform access
The “access position” is the only one from which loading or unloading of persons and materials is allowed. The “access
position” to the work platform is the completely lowered configuration.
To get on the platform:
get on the platform hanging on to the entry side rails.
Raise the bar and get on board.
Check that, once you are on the platform, the bar falls
down closing the access. Fasten the safety harness to the
provided hooks.
To get on the platform use only the
access equipment the platform is
provided with.
When moving up or down, always
keep your eyes on the machine and
hold onto the entry stringers.
IT IS FORBIDDEN
Lock the closing bar so as to keep the
platform access door open.
Fig. 10
IT IS FORBIDDEN
To leave or access the work platform if it is not in the position required for accessing or
leaving.
With the ground control panel (see paragraph “Ground control panel”) it is possible, operating the boom, to lower the
height of access to the platform for a better access to the platform itself.
5.4. Machine start-up
To start the machine the operator shall:
release the emergency stop button on the ground control panel by rotating it of 1/4 turn clockwise;
turn the on-off key on the ground control panel to "Platform" position
remove the starting key and hand it over to a person in charge on ground, properly informed of the use of the
emergency controls
get onto the platform
release the emergency stop button on the platform control panel by rotating it by 1/4 clockwise (see previous
paragraphs).
As the machine is electric-powered (models “E”), now the various functions can be performed by thoroughly following
the instructions given in the previous paragraphs. To turn on the machine, the battery charger must be disconnected
from the mains. If the battery charger is working, the machine is off and cannot be turned on.
Before using the thermic drive power (Diesel motor generator) check the fuel level in the tank through the visual level on
the tank.
Keep the fuel tank and the motor clean.