The user interface display is also used during any interventions by specialized personnel to calibrate/adjust
the working parameters of the machine. This function is not available to the user.
5.2.5. Powered-on machine warning light (E)
The green light lit up indicates that the machine is powered-on (both with platform control panel and ground control panel).
5.2.6. Battery recharge indicator (F)
They allow to check the correct operation of the battery charger and the state of charging of the battery.
After plugging into the mains, the indicator starts flashing for a few seconds with red light, checking phase of the battery. Then the
phases of battery charge are started and displayed in sequence from fixed light first red, then yellow and finally green, which
indicates the end of charging.
No light or long flashing during battery charger feeding indicates malfunctioning.
5.2.7. Diesel motor generator warning lights (G H L M) - OPTIONAL
These warning lights indicate operational faults in Diesel motor generator. One of these warning lights turns ON when the motor
generator is stopped. A “fault” message is sent to the operator on the platform (see paragraph “Platform control panel”).
Once the Diesel motor generator has stopped due to a problem signalled by one of these warning lights, the motor can no longer
be re-started until such problem has been solved.
5.2.8. Levers of movement of the platform (N O P Q R S T U)
The various levers shown in the figure allow the platform to be operated. According to the various signs the corresponding
movements are activated. These controls can be operated only if the on-off key is set to ON down (ground control panel selected).
We shall also remind you that the ground controls are to be used to operate the platform only in emergency situations and must not
be used for any other purposes.