To resume the operations:
On the platform control panel:
turn the emergency stop button of 1/4 turn clockwise;
On the ground control panel:
turn the emergency stop button of 1/4 turn clockwise;
Pull the power circuit red emergency STOP button to the outside - until it locks in position - to power the unit
again.
5.5.3. Diesel motor generator stop
In order to stop the Diesel motor generator:
On the platform control panel:
Turn the starter key anticlockwise to position “0”.
Otherwise, press the emergency stop button.
On the ground control panel:
Turn the starter key anticlockwise to position “0”.
Otherwise, press the emergency stop button.
5.6. Emergency manual controls
This function is to be used only in emergency situations, when no motive power is available.
Fig. 11
In case of fault in the electric or hydraulic system, carry out the following emergency procedures:
1) Push and turn the actuator on the solenoid valve EV11B (A).
2) Remove the lever (B) from its housing by removing the seal and screw it into the distributor that you intend to
operate (C).
3) Remove the operating lever of the manual pump (D) and insert it on the pump.
4) Operate the emergency pump (E) by operating at the same time the distributor lever previously inserted in the
desired direction, considering the manoeuvre you want to achieve.
5) Check the correct execution of this procedure.