Parameter Set-up:
Server IP: enter the IP address of the Akuvox EC32 controller server.
Port: enter the port of Akuvox EC32 controller server.
Timeout (Sec): enter the lift controller timeout. For example, if you set the
timeout as “30 seconds” have to press the lift button corresponding to the
floor you are going to within 30 seconds, otherwise, the button will be locked
again, and you have to go out of the lift and do it all over again.
User Name: enter the user name of the lift controller for the authentication.
Password: enter the password of the lift controller for the authentication.
Floor NO. Parameter: enter the Floor number parameter provided by
Akuvox. The default parameter string is $floor”. You can define your own
parameter string if needed.
URL To Trigger Specific Floor: enter the Akuvox life control URL for
triggering a specific floor. The URL is /cdor.cgi?open=0&door=$floor”, but
the string “$floor” at the end must be identical with the parameter string you
AKUVOX SMART INTERCOM www.akuvox.com

Table of Contents

Other manuals for Akuvox R20A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Akuvox R20A and is the answer not in the manual?

Akuvox R20A Specifications

General IconGeneral
AudioBuilt-in Microphone and Speaker
InstallationWall-mounted
Ingress ProtectionIP65
Card Reader13.56MHz, Mifare
RS485Yes
Camera2MP
Network10/100Mbps Ethernet
ProtocolsSIP
PowerPoE or 12V DC
PoEIEEE 802.3af
Relays1
Input2

Related product manuals