High” and “Low” according to the actual operation on the exit button.
Action To Execute: select the method to carry out the action among four
options: FTP, Email, HTTP, TFTP.
Http URL: enter the URL if you select the HTTP to carry out the action.
Action Delay: set up the delay time when the action is carried out. For
example, if you set the action delay time at 5 seconds, then the
corresponding actions will be carried out 5 minutes after your press the
button.
Execute Relay: set up relays to be triggered by the actions.
Door Status: display the status of the input signal.
16.Security
16.1.Tamper Alarm Setting
Tamper alarm function serves as a protection against any unauthorized removal
of the devices by triggering off the temper alarm while sending out calls to the
designated location. Tamper alarm will be triggered off when the door phone
changes its gravity value as opposed to its original gravity value set up when the
device is installed. You can navigate to Security > Basic > Temper Alarm.
Parameter Set-up:
Tamper Alarm: enable the anti-theft alarm function.
AKUVOX SMART INTERCOM www.akuvox.com

Table of Contents

Other manuals for Akuvox R20A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Akuvox R20A and is the answer not in the manual?

Akuvox R20A Specifications

General IconGeneral
AudioBuilt-in Microphone and Speaker
InstallationWall-mounted
Ingress ProtectionIP65
Card Reader13.56MHz, Mifare
RS485Yes
Camera2MP
Network10/100Mbps Ethernet
ProtocolsSIP
PowerPoE or 12V DC
PoEIEEE 802.3af
Relays1
Input2

Related product manuals