59
Password: enter the password for the HTTP command. For example:
12345”.
Please refer to the following example:
http://192.168.35.127/fcgi/do?
action=OpenDoor&UserName=admin&Password=12345&DoorNum=1
15.7.Configure Exit Button for Door Unlock
When you need to open the door from inside using the Exit button installed by
the door, you can configure the door phone Input to trigger the relay for the door
access on web Intercom > Input interface.
Parameter set-up:
Enabled: enable the function if needed.
Trigger Electrical Level: select the trigger electrical level options between
Note:
DoorNum in the HTTP command above refers to the relay number
#1 to be triggered for the door access.