At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Carefully remove and reseat the pluggable module that is reporting the FACTERM-DEV
condition.
...................................................................................................................................................................................................
2
Remove and cap the fiber jumpers connected to the pluggable module and replace the
pluggable module with another unit of the same type. Refer to “Replacing an SFP
Module”
(p. 3-27). Reconnect the fiber jumpers as they were before.
...................................................................................................................................................................................................
3
Perform a warm reset of the card.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
4
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
5
Reseat the card. Refer to “Reseating a Card” (p. 3-19).
...................................................................................................................................................................................................
6
Replace the card. Refer to “Replacing System Components” (p. 3-20). Follow the return
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
FANSPEEDHIGH
FANSPEEDHIGH (Fan Speed is too high)
Trouble-clearing procedures
FACTERM-DEV
FACTERM-DEV (Pluggable Module SEEP Failure)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-90
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................