At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
If the LANLFI condition has been raised on a client port, verify that the source is
correctly transmitting the Ethernet signal. Refer to its manufacturer's documentation for
any corrective actions.
...................................................................................................................................................................................................
2
If the LANLFI condition has been raised on a Network port, retrieve the alarm
information from the upstream path to determine if any failure is present. If there is an
indication of failure upstream of the port where the LANLFI is raised, fix this problem
first.
...................................................................................................................................................................................................
3
Perform a warm reset on the card where the LANLFI condition is raised.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
4
Perform a cold reset on the card where the LANLFI condition is raised.
Note: Refer to Caution at the beginning of this procedure.
CLI config card card type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
5
Reseat the card. Refer to “Reseating a Card” (p. 3-19).
...................................................................................................................................................................................................
6
Replace the card. Refer to “Replacing System Components” (p. 3-20).
LANLOS
LANLOS (LAN port LOS)
Trouble-clearing procedures
LANLFI
LANLFI (Local Fault)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-121
E ND OF STEPS
...................................................................................................................................................................................................