MISMATCH (Power Filter Mismatch)
The Power Filter Mismatch alarm indicates that the two power filters do not have
matching current carrying capacity or do not match the preprovisioned filter type. The
Power Filter Mismatch alarm could also indicate that power filter Wavelength Tracker
function does not match the shelf Wavelength Tracker mode. This alarm can also occur
after a new installation on a PSS-32 drop shelf configuration.
Severity Minor
Service affecting? No
Applicability PF
Corrective Action
...................................................................................................................................................................................................
1
At the end of each step wait to see if the fault clears. If not, continue with the next step.
If... Then...
the Power Filter Mismatch alarm is raised after
a new installation on a PSS-32 drop shelf
configuration,
proceed to Step 7.
the
Power Filter Mismatch alarm is raised for
any other reason,
continue with Step 2.
...................................................................................................................................................................................................
2
Identify the power filter model engineered for the installation.
...................................................................................................................................................................................................
3
Equip the correct matching power filters.
...................................................................................................................................................................................................
4
Identify whether the PF Wavelength Tracker function matches shelf Wavelength Tracker
mode. (For example, PFDCA does not support Wavelength Tracker.)
...................................................................................................................................................................................................
5
Set the Wavelength Tracker mode of the shelf to the correct mode.
...................................................................................................................................................................................................
6
Provision the shelf EXPECTED_AMPS parameter with the correct value: 30, 50, or 70
amps.