This may be caused by the following reasons:
• A misconnected, damaged or dirty fiber
• Received power may not be within the acceptable range
Severity MJ
Service affecting? Yes
Applicability 11DPE12, 11DPE12E, A2325A, AHPHG, AHPLG, ALPHG,
AM2017B, AM2125A, AM2125B, AM2325B
No corrective action is required. Refer to the corrective action for the LINE port LOS
alarm (see “LD Input LOS” (p. 2-153)).
Trouble-clearing procedures
RAMANSUP
RAMANSUP (Raman Suppress - Line)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-277