WKSWPR
WKSWPR (Automatic switch to protection)
This is a standing condition indicating that the protection facility/equipment is active.
This condition is raised only when reversion is enabled.
If the working facility/equipment is error-free then the condition automatically clears
once the wait-to-restore timer has expired.
Severity Not alarmed
Service affecting? No
Applicability 11STAR1, 11STMM10, 11STGE12, 4DPA4, OPS
Corrective Action
The action required to clear this condition depends on whether or not there are
outstanding problems against the working facility/equipment.
At the end of each step wait to see if the fault clears. If not, continue with the next step.If
there are no faults against working facility/equipment:
...................................................................................................................................................................................................
1
Wait for the wait-to-restore timer to expire.
...................................................................................................................................................................................................
2
Display the protection group for the associated shelf/slot/port.
CLI config aps group group detail
...................................................................................................................................................................................................
3
Initiate a manual switch to work.
CLI config aps group group manualSwitchtoWorking
...................................................................................................................................................................................................
4
Clear the manual switch.
CLI config aps group group clearSwitch