config database backup
...................................................................................................................................................................................................
3
Replace the Equipment Controller.
The Equipment Controller will have a DBINVALID alarm active after the reboot has
completed.
...................................................................................................................................................................................................
4
If... Then...
the Equipment Controller is new from the
factory or does not contain the desired
software release,
continue with Step 5
the Equipment Controller has the current
desired
software,
proceed to Step 13.
...................................................................................................................................................................................................
5
To configure or verify the OAMP port details, type
config interface usrpnl oamp ip IP address/subnet mask.
A warning is displayed:
WARNING: Changing the OAMP ethernet port IP address may result
in a loss of IP connectivity to this and other network elements.
Type yes to confirm the configuration.
...................................................................................................................................................................................................
6
To configure or verify the TID, type config general name NE name.
...................................................................................................................................................................................................
7
To configure or verify the loopback IP address, type
config interface loopback ip loopback IP address/subnet mask.
A warning is displayed:
WARNING: Changing the loopback IP address will result in a warm
reset of this network element.
Type yes to confirm the configuration.
...................................................................................................................................................................................................
8
To configure or verify static routes, type config cn routes default add gateway
default IP address.
Supporting procedures
Replacing System Components
Replacing an Equipment Controller in a Nonredundant Shelf
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
3-47