Interfaces
Page 182 7750 SR Interface Configuration Guide
Basic Configuration
The most basic configuration must have the following:
Identify chassis slot.
Specify line card type (must be an allowed card type).
Specify MCM slot for 7750 SR-c4 and SR-c12 only (not required for CMA)
Specify MCM type 7750 SR-c4 and SR-c12 only (must be an allowed MCM type)
Identify MDA slot.
Specify MDA (must be an allowed MDA type).
Identify specific port to configure.
The following example displays some card configurations:
ALA-A>config# info
#------------------------------------------
# Card Configuration
#------------------------------------------
card 1
card-type iom-20g
mda 1
mda-type m60-10/100eth-tx
exit
mda 2
mda-type m60-10/100eth-tx
exit
exit
card 2
card-type iom-20g
mda 1
mda-type m10-1gb-sfp
exit
mda 2
mda-type m10-1gb-sfp
exit
exit
card 3
card-type iom-20g
mda 1
mda-type m12-ds3
exit
mda 2
mda-type m12-ds3
exit
exit
card 8
card-type iom-20g
mda 1
mda-type m8-oc12/3-sfp
exit
mda 2
mda-type m16-oc12/3-sfp

Table of Contents