EasyManua.ls Logo

Alcatel-Lucent 7750 - Table 5: DDM Alarms and Warnings

Alcatel-Lucent 7750
788 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interface Configuration
7750 SR Interface Configuration Guide Page 35
The factory-programmed DDM alarms and warnings that are supported are summarized in
Table 5.
Table 5: DDM Alarms and Warnings
Parameter SFP/XFP Units SFP XFP Required? MSA DWDM
Temperature
- High Alarm
- Low Alarm
- High Warning
- Low Warning
CYesYesYesYes
Supply Voltage
- High Alarm
- Low Alarm
- High Warning
- Low Warning
µV Yes Yes Yes No
TX Bias Current
- High Alarm
- Low Alarm
- High Warning
- Low Warning
µA YesYesYesYes
TX Output Power
- High Alarm
- Low Alarm
- High Warning
- Low Warning
mW YesYesYesYes
RX Optical Power
- High Alarm
- Low Alarm
- High Warning
- Low Warning
mW YesYesYesYes
AUX1
- High Alarm
- Low Alarm
- High Warning
- Low Warning
parameter
dependent
(embedded in
transceiver)
No Yes Yes No
AUX2
- High Alarm
- Low Alarm
- High Warning
- Low Warning
parameter
dependent
(embedded in
transceiver)
No Yes Yes No

Table of Contents