Interfaces
Page 196 7750 SR Interface Configuration Guide
exit
no-shutdown
----------------------------------------------
A:ALA-274>config>port# aps-1
----------------------------------------------
aps
working-circuit 1/1/1
protect-circuit 1/1/2
exit
sonet-sdh
path
atm
exit
no-shutdown
exit
exit
no-shutdown
exit
----------------------------------------------
A:ALA-274>config>service# apipe 100
----------------------------------------------
sap aps-1:0/100 create
exit
spoke-sdp 1:100 create
exit
no-shutdown
----------------------------------------------
The following displays an example of the configuration for the working circuit/node of a MC-APS
group:
A:ALA-274>config>port (2/1/1)# info
----------------------------------------------
description "APS Group"
aps
neighbor 13.1.1.2
working-circuit 2/1/1
exit
no shutdown
----------------------------------------------
A:ALA-274>config>port#
The following displays an example of the configuration for the protect circuit/node of a MC-APS
group:
A:ALA-274>config>port (2/2/2)# info
----------------------------------------------
description "APS Group"
aps
neighbor 13.1.1.1
protect-circuit 2/2/2
exit
no shutdown
----------------------------------------------
A:ALA-274>config>port#