Page 328 7750 SR Interface Configuration Guide
config>port>access>egress>pool
config>port>access>ingress>pool
config>port>network>egress>pool
Description This command configures the threshold for the amber alarm on the over-subscription allowed.
Users can selectively enable amber or red alarm thresholds. But if both are enabled (non-zero) then the red
alarm threshold must be greater than the amber alarm threshold.
The no form of the command reverts to the default value.
Default 0
Parameters percentage — Specifies the amber alarm threshold.
Values 1 — 1000
red-alarm-threshold
Syntax red-alarm-threshold percentage
no red-alarm-threshold
Context config>card>mda>access>egress>pool
config>card>mda>access>ingress>pool
config>card>mda>network>egress>pool
config>card>mda>network>ingress>pool
config>port>access>egress>pool
config>port>access>ingress>pool
config>port>network>egress>pool
Description This command configures the threshold for the red alarm on the over-subscription allowed.
Users can selectively enable amber or red alarm thresholds. But if both are enabled (non-zero) then the red
alarm threshold must be greater than the amber alarm threshold.
The no form of the command reverts to the default value.
Default 0
Parameters percentage — Specifies the amber alarm threshold.
Values 1 — 1000
slope-policy
Syntax slope-policy name
no slope-policy
Context config>port>access>egress>pool
config>card>mda>access>egress
config>card>mda>access>ingress
config>card>mda>network>egress