Page 352 7750 SR Interface Configuration Guide
psi-tti
Syntax psi-tti
Context config>port>otu
Description This command enables the context to configure payload structure identifier trail trace identifier parameters.
tx
Syntax tx {string identifier | bytes byte-sequence | auto-generated}
Context config>port>otu>psi-trace
Description This command allows the user to configure the transmit trace in bytes 1 to 255 (skipping byte 0) of the pay-
load structure identifier (PSI) of the OPU overhead. This identifier can be a string or a non-printable
sequence of bytes. The length of the string or sequence of bytes cannot exceed 255 bytes.
Default Blank (all zeros)
Parameters auto-generated — Sets the default PSI trace
string identifierSets the PSI trace to the string provided by the user. If the string is less than 255 bytes,
the remaining bytes will be set to 0.
bytes byte1 [byte2...(up to 64 bytes)]Sets the PSI trace to the sequence of bytes provided by the user. If
the user provides less than 64 bytes, the remaining bytes will be set to 0. A 1 byte sequence of 0xFF will
set the default strings.
Values 0 — FF, in hexidecimal byte notation
expected
Syntax expected {string string | bytes byte-sequence | auto-generated | use-rx}
Context config>port>otu>pm-tti
Description This command allows the user to configure the expected RX in bytes 1 to 255 (skipping byte 0) of the Pay-
load structure identifier (PSI) of the OPU overhead. This identifier can be a string or a non-printable
sequence of bytes. The length of the string or sequence of bytes cannot exceed 255 bytes. This trace should
match the far-end port's PSI trace. When this trace does not match the received PSI trace, the OPU-TIM
alarm will be reported if enabled.
Default Blank (all zeros)
Parameters auto-generated — Sets the default
string string — Sets the PSI trace to the string provided by the user. If the string is less than 64 bytes, the
remaining bytes will be set to 0.
bytes — [byte1 byte2 ... byte64]. Sets the PSI trace to the sequence of bytes provided by the user. If the user